Model No | BESS G10 | ||
Battery Input Data | |||
Battery Type | LFP(LiFePO4) | Voltage Range | 44.8-57.6V |
Confifiguration
|
2P16S | Rated Charging Current | 100A |
Rated Voltage | 51.2V | Rated Capacity | 200Ah |
Max. Charging Current | 120A | Max. Discharging Current | 120A |
Rated Energy |
10.24kWh
|
Rated Discharging Current | 100A |
PV Parameters | |||
Max. PV Generation Power |
6500W
|
Max. Short Circuit Current | 13.8/13.8A |
Max. DC Voltage | 580V | MPPT Voltage Range | 125-550V |
Rated DC Operating Voltage | 360V | MPPT Number | 2 |
Max. PV Input Current | 11/11A | ||
On-Grid Parameters |
|||
On-Grid Rated Power | 5000VA | On-Grid Rated Current | 21.7A |
On-Grid Rated Voltage | 230V | Max. AC Current | 24.5A |
On-Grid Rated Frequency | 50/60Hz | Power Factor | 0.8 lead~0.8 lag |
Electrical Connection | L/N/PE | THD | <3% |
Parallel Operation | NO | ||
Off-Grid Parameters | |||
Off-Grid Rated Power | 4600VA | ||
Off-Grid Rated Voltage | 230V | ||
Off-Grid Rated Frequency | 50/60Hz | ||
Electrical Connection | L/N/PE | ||
Max. Protection Current | 30A | ||
Max. Short Circuit Current | 43A (10s) | ||
Peak Power | 6900VA (3s) | ||
UPS Switching Time | <0.5S | ||
Operating Conditions | |||
Ambient Temperature | Charge/Discharge: 0~55°C | ||
Humidity | 5~95%, no condensing | ||
Altitude | ≤2000m | ||
Mounting | Floor standing | ||
General Parameters | |||
Weight | 160kg | ||
Dimensions (W*D*H) | 700*212*1320mm | ||
Protection Rating | IP65 | ||
Cooling | Natural cooling | ||
Cycle Life | ≥6000 cycles (@25±2°C, 0.5C/0.5C, 90%DOD, 70%EOL) | ||
Certififications | IEC62619, UL1973, UL9540, UN38.3, CE |